Medc Weatherproof FernTel User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
25
Technical Data
Connection data
Supply voltage 24….66 Vdc
Supply current 19…100 mA
Ringing alternating current 30….90 Vac
Ringing frequency 16….68 Hz
Ringer input impedance ≥ 6.0 k at 25 Hz
≥ 3.5 k at 50 Hz
Enquiry key (flash) only for DTMF 80 ms, 120 ms, 600 ms
Dialling mode
DTMF Frequencies according to ITU-T Q.23
Tone duration unlimited or 90 ms
PD Pulse/Pause ratio
1.5:1 (60/40 ms) or
2:1 (66.7/33.3 ms)
Ringing volume max. approx. 95 dB(A) at 1 m distance
Housing 293 x 191 x 128 mm
(Height x Width x Depth)
Weight approx. 2.300 g
(telephone incl. telephone mount)
Display 2 lines, 16 positions per row, 7x 5 matrix
Pictograms
Operating utilization position Table or vertical wall mounting
Handset
Mouthpiece Electret-foil microphone
Receiver inset dynamic receiver inset with magnetic field generator
Connections Single- or multiwired up to 2.5 mm
2
Labelling
Power cable TCP/La – TCP/Lb (TCP : Terminal Connection Point)
Secondary sounder W / W1
Environmental conditions
Ambient operating temp. -25°C...+60°C
(Below -20°C there is no readout on the display)
Transport and storage temp. -25°C...+70°C
Degree of protection
acc. to IEC60529 IP65
Protection against external
mechanical stress Degree of protection IK08 according to EN50102