6. The stipulated position of utilisation must be adhered to. The
telephone must be installed on a plane surface only, in vertical
operating position.
7. Magnetic fields with energy technical frequencies can cause a slight
impairment of the listening quality. If this is the case, please ensure
that the telephone is installed at a suitable location.
8. The type of protection of the telephone is:
II 2 G Ex emb [ib] IIC T5 Ex emb [ib] IIC T5
II 2 D Ex tD A21 IP66 T100°C Ex tD A21 IP66 T100°C
-25°C ≤ T
a
≤ +60°C -25°C ≤ T
a
≤ +60°C
Ex emb [ib] IIC T6
II 2 G Ex emb [ib] IIC T6 Ex tD A21 IP66 T80°C
II 2 D Ex tD A21 IP66 T80°C -25°C ≤ T
a
≤ +40°C
-25°C ≤ T
a
≤ +40°C IECEx BVS 11.0033
9. The telephone must be switched off before opening. Wait at least 2
minutes after switching off power before opening the telephone!
10. In the open state of the telephone no dust may ingress the device.
11. Upon mounting or demounting the device, do not damage the cover
seal, which keeps the cover tight, or the collar on the lower part of
the housing.
12. Upon repairing the apparatus for use in dust, the repaired parts
should once again be subjected to a routine test.
13. The mouthpiece horn of the receiver consists of a non-conductive
plastic material. It may become dangerously charged at high air
speeds. Consequently, cleaning the mouthpiece horn with
pressurized air is prohibited.
14. If there is a high concentration of sulphurous gases in the
environment, the lettering of the keys can fade and a rust film can
arise.
15. Changes to the product which are in the interests of technical
progress are possible even without prior notice.